| 04416A1 | SERVOPRO NanoChrome Ar Background |
| includes report software, packaging | |
| Impurities options | |
| N2 Range 0-250ppb LDL 0.3ppb | INJ with 1 valve |
| H2 Range 0-250ppb LDL 0.5ppb | INJ/HC with 2 valves |
| CO Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb | BF/HC/SEL with 3 valves |
| Chassis options (Refer to SAP) | |
| Master Chassis | Max. 2 channels with 4 valves |
| PC+ Slave chassis | 2 BF/HC channels |
| Master +Slave1 Chassis | Max. 4 channels with 8 valves |
| Carrier Gas | Helium |
| Argon only for N2 measurement | |
| Power | 115 VAC, 50-60 Hz |
| 220 VAC, 50-60 Hz | |
| Gas Connectors (to match accessories fittings) | 1/8" VCR |
| Serial port | RS-232 |
| Remote Support | VNC |
| Net Support | |
| Internal Dilution System | Not Required( > 1ppm) |
| Required ( One per Chassis) | |
| 04416A1 | SERVOPRO NanoChrome N2 Background |
| includes report software, packaging | |
| Impurities options | |
| Ar Range 0-250ppb LDL 0.5ppb | INJ/HC with 2 valves |
| H2 Range 0-250ppb LDL 0.5ppb | INJ/HC with 2 valves |
| CO Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb | BF/HC/SEL with 3 valves |
| Chassis options | |
| Master Chassis | Max. 2 channels with 4 valves |
| PC+ Slave chassis | 2 BF/HC channels |
| Master +Slave1 Chassis | Max. 4 channels with 8 valves |
| Master +Slave 1 +Slave 2 Chassis | Max. 6 channels with 12 valves |
| Carrier Gas | Helium |
| Power | 115 VAC, 50-60 Hz |
| 220 VAC, 50-60 Hz | |
| Gas Connectors (to match accessories fittings) | 1/8" VCR |
| Serial port | RS-232 |
| Remote Support | VNC |
| Net Support | |
| Internal Dilution System | Not Required( > 1ppm) |
| Required ( One per Chassis) | |
| SERVOPRO Plasma Gas Analyser (K2001) | |
| 02001A1 | Trace Gas Analyser |
| includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging) | |
| Power | 115 VAC, 50-60 Hz |
| 220 VAC, 50-60 Hz | |
| Background | Argon |
| Helium | |
| Argon and Helium | |
| Auto calibration | Not required |
| Required | |
| 3 Range ID | 0-1, 0-10, 0-100 (ppm) |
| 0-10, 0-50, 0-100 (ppm) | |
| Serial port | Not Required |
| RS-232 | |
| SERVOPRO Chroma Gas Analyser (K4000) | |
| 04401A1 | Crude Ar Analyser (N2 in mix 10%Ar + 90%O2) Base |
| includes report software, 2 SS coils tubing, packaging | |
| Trace (>10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
| 0-10ppm ≤N2 range ≤ 0-500ppm LDL is 1.5% full scale | |
| Carrier Gas | Argon |
| Power | 115 VAC, 50-60 Hz |
| 220 VAC, 50-60 Hz | |
| Gas Connectors | 1/8" Swagelok |
| (to match accessories fittings) | |
| Serial port | Not Required |
| RS-232 | |
| Remote Support | VNC |
| Net Support | |
| Dual Inlets (sample + span, with switching) | Not Required |
| Required | |
| Calibration using background gas | Not required |
| Required |




Hotline