Loa Chống cháy nổ GNExS2 BExH120 Alarm Horn Sounder 123dB(A) E2S Vietn, STC Vietnam
STExS2F Alarm Horn Sounder
The STExS2F is a high output, 123dB(A) alarm horn sounder with a re-entrant flare horn. The robust IP66 corrosion proof 316L stainless steel enclosure ensures the STExS2F is suitable for all Zone 1, 2, 21 & 22 explosion proof signalling applications.
Featuring 64 first stage/channel alarm sounds which can be selected via an internal switch. The alarm tone frequencies for the first 2 stages are independently selectable. Each tone can be remotely triggered e.g. via an external relay, to change to a second, third or fourth stage/channel alarm sound. The enclosure features a threaded flame path, triple cable entries and a large termination area - all of which significantly reduce installation time.
Specification
Maximum output: | 123dB(A) @ 1 metre [114dB(A) @ 10ft/3m] |
Nominal output: | 117dB(A) @ 1m +/- 3dB - Tone 2 [103dB(A) @ 10ft/3m] |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Adjustable -12dB(A) [Tone 2] |
Effective range: | 200m/656ft @ 1KHz |
Voltages DC: | 24V dc (10-30V dc) |
Voltages AC: | 110-240V ac 50/60Hz |
Stage switching: | DC units: negative or positive AC units: common supply line |
Ingress protection: | EN60529: IP66 |
Enclosure matl: | 316L Stainless Steel |
Enclosure finish: | Chromated & powder coated |
Colour: | Red (RAL3000) |
Cable entries: | 3 x M20 x 1.5mm |
Terminals: | 0.5 - 2.5mm² (20-14 AWG) |
Enclosure volume: | <2 litres |
Line monitoring: | Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted |
Grounding stud: | M5 |
Operating temp: | -50 to +70°C [-58° to +158°F] |
Relative humidity: | 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist |
Weight: | 6.55kg/14.44lbs |
Part Codes
Version: | Part code: | ||
---|---|---|---|
Product type: | STExS2 | ||
Horn type: | F | Flare re-entrant horn | |
Voltage: | DC024 AC230 |
10-30V dc 110-240V ac |
|
Cable Entry Type:[e] Note: |
A B C D E F G |
3 x M20x1.5mm 2 x 1/2" NPT - adaptors 2 x 3/4" NPT - adaptors 2 x M25x1.5mm - adaptors 1 x 1/2" NPT - adaptor 1 x 3/4" NPT - adaptor 1 x M25x1.5mm - adaptor M20 stopping plugs for unused entries supplied with all options |
|
Adaptor/Stopping plug material: [m] |
B N S |
Brass Nickel Plated Stainless Steel (standard) |
|
Bracket material: [s] | 1 2 3 4 |
A2 304 Stainless Steel A4 316 Stainless Steel (default) A2 304 St/St with Equip. Tag A4 316 St/St with Equip. Tag (304) |
|
Product version: [v] | A1 | IECEx & ATEX Group II 2G/D Zone 1, 2, 21 & 22 | |
Enclosure colour: [x] | R | Red RAL3000 |
Alarm sounder
Version: | Voltage: | Current: | |
---|---|---|---|
10-30V dc | 24V dc | 924mA | |
110-240V ac | 50/60Hz | 115V ac | 268mA |
110-240V ac | 50/60Hz | 230V ac | 159mA |
Coding
- Ex db IIC Gb T6 Ta -50°C to +45°C
- Ex db IIC Gb T5 Ta -50°C to +60°C
- Ex db IIC Gb T4 Ta -50°C to +70°C
- Ex tb IIIC Db T105°C Ta -50°C to +70°C