Loa đèn chống cháy nổ STExC1X05F, D1xC2X10R Alarm Horn & Xenon Strobe E2S Vietnam, STC Vietnam
Hãng sản xuất: Nex Flow
Ứng dụng sản phẩm: Sắt thép, gỗ, Thực phẩm, thủy tinh, bao bì, bia, rượu, xi măng,dệt may,dầu khí,sx ô tô, cơ khí...
D1xC2X05R Radial Alarm Horn & Xenon Strobe
118dB(A) horn & 5 Joule Xenon. The D1xC2X05R is a high output alarm horn sounder with omni-directional radial horn combined with a 500,000cd Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure ensures the D1xC2X05R is suitable for all Class I & II Division 1, Zone 1 & 20 explosion proof signaling applications. The Class I DC version is approved for public mode fire alarm use (alarm horn) and private mode fire alarm use (strobe beacon).
Specification
Alarm Horn: | |
Maximum output: | 118dB(A) @ 1 metre [109dB(A) @ 10ft/3m] |
Nominal output: | 112dB(A) @ 1m +/- 3dB - Tone 8 [103dB(A) @ 10ft/3m] |
No. of tones: | 64 (UKOOA / PFEER compliant) |
No. of stages: | 4 |
Volume control: | Adjustable -12dB(A) |
Effective range: | 125m/410ft @ 1KHz |
Supply Voltages: | 24Vdc; 115Vac; 230Vac |
Stage switching: | DC units: negative or positive AC units: common supply line |
Strobe Beacon: | |
Energy: | 5 Joules (5Ws) |
Flash rates: | Option 1: 1Hz (60 fpm) Option 2: 1.5Hz (90 fpm) Option 3: Double Strike |
Peak Candela: | 500,000 cd - calculated from energy (J) |
Effective Intensity: | 250 cd - calculated from energy (J) |
Peak Candela: | 46,976 cd* - measured ref. to I.E.S. |
Effective Intensity: | 143 cd* - measured ref. to I.E.S. |
Lens colours: | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
Tube life : | Emissions are reduced to 70% after 8 million flashes |
General: | |
Ingress protection: | EN60529: IP66 UL50E / NEMA250: 4 / 4X / 3R / 13 |
Enclosure material: | Marine grade aluminium LM6- copper free Chromated & powder coated - corrosion proof |
Colour: | Red (RAL3000), Grey (RAL7038) |
Cable entries: | 1 x 1/2"NPT & 2 x M20 x 1.5mm 1 x 1/2"NPT & 2 x 1/2"NPT 1 x 1/2"NPT & 2 x 3/4"NPT |
Terminals: | 0.5 - 2.5mm² (20-14 AWG) |
Grounding stud: | M5 |
Operating temp: | 24Vdc & 115Vac: -40° to +70°C [-40° to +158°F] 230Vac: -40° to +55°C [-40° to +131°F] |
Storage temp: | -50° to +70°C [-58° to +158°F] |
Relative humidity: | 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist |
Weight: | 5.0kg/11.1lbs |
Current Consumption
Voltage: | Range: | Alarm Horn | Xenon Strobe | Combined | |
---|---|---|---|---|---|
24V dc | 20-28Vdc | 923mA | 322mA | 1245mA | |
115V ac | 110-120Vac 50/60Hz |
267mA | 129mA | 396mA | |
230V ac | 220-240Vac 50/60Hz |
159mA | 79mA | 238mA |
Part Codes
Version: | Part code: | ||
---|---|---|---|
Product type: | D1xC2X05 | ||
Horn type: | R | Omni-directional radial horn | |
Voltage: | DC024 AC115 AC230 |
20-28V dc 110-120V ac 220-240V ac |
|
Cable Entry Type:[e] | A B C |
1 x 1/2"NPT & 2 x M20 x 1.5mm 1 x 1/2"NPT & 2 x 1/2"NPT 1 x 1/2"NPT & 2 x 3/4"NPT |
|
Adaptor/Stopping plug material: [m] |
B N S |
Brass Nickel Plated Stainless Steel |
|
Bracket/Guard material: [s] | 1 2 3 4 |
A2 304 Stainless Steel A4 316 Stainless Steel A2 304 St/St with Equip. Tag A4 316 St/St with Equip. Tag (304) |
|
Product version: [v] | A1 D1 |
Gas environments Class I/Zone1 Dust environments Class II/Zone 20 |
|
Enclosure colour: [x] | G R |
Grey RAL7038 Red RAL3000 |
|
Lens colour: [y] | A, B, C, G M, R, Y |
Amber, Blue, Clear, Green Magenta, Red, Yellow |
|
Example: | D1xC2X05RAC230 [e][m][s][v][x][y] D1xC2X05RAC230AB1A1R/A |
||
Ratings: | |||
A1: | Gas version | ||
NEC / CEC: | Class I Div 1 ABCD T5/T6 Ta -40°C to +55/+50°C Class I Div 2 ABCD T5/T6 Ta -40°C to +55/+50°C Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +55/+50°C |
||
D1: | Dust version | ||
NEC / CEC: | Class II Div 1 FG T4/T4A Ta -40°C to +55/+40°C Class II Div 2 FG T4/T4A Ta -40°C to +55/+40°C Class III Div 1&2 Zone 20, 21, 22 IIIB T4/T4A Ta -40°C to +55/+40°C |
Coding
- A1: Gas version
NEC / CEC:
Class I Div 1 ABCD T5/T6 Ta -40°C to +55/+50°C
Class I Div 2 ABCD T5/T6 Ta -40°C to +55/+50°C
Class I Zone 1, 2 IIC T5/T6 Ta -40°C to +55/+50°C - D1: Dust version
NEC / CEC:
Class II Div 1 FG T4/T4A Ta -40°C to +55/+40°C
Class II Div 2 FG T4/T4A Ta -40°C to +55/+40°C
Class III Div 1 & 2
Zone 20, 21, 22 IIIB T4/T4A Ta -40°C to +55/+40°C - Protection concept: Ex d / AEx d
Effective Candela lens colour factor
Amber | Blue | Clear | Green | Red | Yellow |
0.70 | 0.24 | 1.00 | 0.25 | 0.23 | 0.93 |