04407A1 Hydrogen Purity Analyser Base
  includes report software, SS liners, packaging
   
Trace (>10 ppm), Pack 1 N2 Impurity - Enter range & LDL
  0-10ppm ≤N2 range ≤ 0-200ppm  LDL is 1.5% full scale
  (with O2 trap in aux oven)
   
Trace (>10 ppm), Pack 2 Same as Pack 1 +
  CO2 Impurity - Enter range & LDL
  0-10ppm ≤CO2 range ≤ 0-200ppm  LDL is 1.5% full scale
  CH4 Impurity - Enter range & LDL
  0-10ppm ≤CH4 range ≤ 0-200ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 3 CO Impurity - Enter range & LDL
  0-10ppm ≤CO range ≤ 0-200ppm  LDL is 1.5% full scale
  CO2 Impurity - Enter range & LDL
  0-10ppm ≤CO2 range ≤ 0-200ppm  LDL is 1.5% full scale
  CH4 Impurity - Enter range & LDL
  0-10ppm ≤CH4 range ≤ 0-200ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 4 Same as Pack 2 +
  CO Impurity - Enter range & LDL
  0-10ppm ≤CO range ≤ 0-200ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 5 Same as Pack 4 +
  Ar Impurity - Enter range & LDL
  0-10ppm ≤Ar range ≤ 0-200ppm  LDL is 1.5% full scale
   
Trace Exact (<10 ppm), Pack 1 N2 Impurity - Enter range & LDL (with O2 trap in aux oven)
  0-1ppm ≤N2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm CO2 Impurity - Enter range & LDL
  0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  CH4 Impurity - Enter range & LDL
  0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 2 CO Impurity - Enter range & LDL
  0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm CO2 Impurity - Enter range & LDL
  0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  CH4 Impurity - Enter range & LDL
  0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Trace Exact (<10 ppm), Pack 2 Same as Pack 1 +
  CO Impurity - Enter range & LDL
Min Range 0-1 ppm 0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
   
Carrier Gas Argon
  Helium (if Argon impurity)
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" Swagelok
  1/8" VCR (if 0-1 ppm range)
   
Serial port Not Required
  RS-232
   
Remote Support VNC
  Net Support
   
Dual Inlets (sample + span, with switching) Not Required
  Required
   
Calibration using background gas Not required
  Required
   
   
   
04408A1 Carbon Dioxide Purity Analyser Base
  includes report software, SS liners, packaging
   
Trace (>10 ppm), Pack 1 O2 Impurity - Enter range & LDL
  0-10ppm ≤O2 range ≤ 0-100ppm  LDL is 1.5% full scale
  H2 Impurity - Enter range & LDL
  0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
  N2 Impurity - Enter range & LDL
  0-10ppm ≤N2 range ≤ 0-100ppm  LDL is 1.5% full scale
  CH4 Impurity - Enter range & LDL
  0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 2 Same as Pack 1 +
  CO Impurity - Enter range & LDL
  0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
   
Trace (>10 ppm), Pack 3 Same as Pack 2 +
  Ar Impurity - Enter range & LDL
  0-10ppm ≤Ar range ≤ 0-100ppm  LDL is 1.5% full scale
   
Carrier Gas Argon
  Helium (if Argon impurity)
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
   
Gas Connectors (to match accessories fittings) 1/8" Swagelok
  1/8" VCR (if 0-1 ppm range)
   
Serial port Not Required
  RS-232
   
Remote Support VNC
  Net Support
   
Dual Inlets (sample + span, with switching) Not Required
  Required
   
Calibration using background gas Not required
  Required
   
   
   
   
SERVOFLEX 5200 MULTI PURPOSE ANALYSER  
   
05230A1 5200 Multi Purpose
   
SUPPLY POWER UK Mains
  European Mains
  US Mains
  Japanese Mains (no plug fitted)
  Rechargeable Lithium ion battery (UK)
  Rechargeable Lithium ion battery (US)
  Rechargeable Lithium ion battery (Euro)
  Rechargeable Lithium ion battery (Japan)
   
MEASUREMENT 1 Oxygen, standard accuracy (1116)
  Oxygen, industrial version (3601, 1 dec place)
  Oxygen, high accuracy (3601, 2 dec place)
  0-10% Carbon Dioxide
  0-25% Carbon Dioxide
  0-50% Carbon Dioxide
  0-100% Carbon Dioxide
   
MEASUREMENT 2 0-10% Carbon Dioxide
  0-25% Carbon Dioxide
  0-50% Carbon Dioxide
  0-100% Carbon Dioxide
   
SAMPLING Automatic Flow Control Device
  Internal Pump
   
mA OUTPUTS mA outputs, one transducer fitted
  mA outputs, two transducers fitted
   
CONNECTORS Quickconnect 1/4" barb fitting
  Barb as above plus adaptor to 1/8" NPT
   
EXHAUST / VENT OUTLETQ Rear Panel
  Front Panel
   
VEHICLE ADAPTOR 12/24V Vehicle Power Adaptor
   
PRINTER* Thermal Printer Kit (Universal)
   
SIDE PANEL ACCESSORIES Sample Conditioning Panel (not for O2 std transducer)
Choose only one Flow Meter + Valve (not for AFCD version)
  Flow Meter (analyser with AFCD)
   
PROBE HOLDER Supplied (for SCP only)
  Supplied including Filter (not for SCP)
   
SAMPLE PROBE Not Supplied
  25cm, SS, Tip, <180C
  1m SS
   
TRANSPORT CASE None
  Protective plastic transport case, std pre-cut foam
   
USER MANUAL English
  French
  German
  Italian
   
ACCESSORIES  
202517 Additional barbed Quickconnect fitting
  (1 supplied as standard. Some users may wish
  to purchase additional fittings for zero and span
  gas to speed connections during calibration)
   
5200991 Additional Quickconnect adaptor to 1/8" NPT
   
203022 Additional rolls of printer paper (pack of 5)
   
570982 Replacement filters (pack of 5)
  NOTE: 3 filters supplied with analyser
   
2323-7029 Replacement Viton O-ring for AFCD
   
5200992 Carry Case with foam inserts
   
Note: If printer ordered as loose item after initial purchase price is higher
209961 Thermal Printer Kit (Universal)***
   
*This price only when purchased with analyser. Includes 1 roll of paper.
   
***The instrument will only print properly to the printer supplied by Servomex.