loa-den-chong-tia-lua-d2xc1x05-d2xc2xh1-alarm-horn-sounder-xenon-strobe-beacon-e2s-vietnam-stc-vietnam.png

D2xC1X05 Alarm Horn Sounder & Xenon Strobe Beacon

The D2xC1X05 features a high output, 116dB(A) alarm horn sounder combined with a 5 Joule Xenon strobe beacon. 
Low current consumption and high SPL in a robust Type 4/4X, IP66 enclosure ensure the D2xC1X05 is suitable for all haz loc fire alarm system and general signalling applications.

The corrosion proof, marine grade aluminium die cast enclosure is phosphated and powder coated providing resilience in the harshest of hazardous location environments.
One device, globally certified: ATEX, IECEx Zone 2 & 22; NEC/CEC CI D2 and CII D2; NEC CI Zone 2 and Zone 22; CEC Zone 2 & 22 and CII D2.
UL & cUL approved 24Vdc version for fire alarm use.

Specification

 
Horn Sounder:
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 112dB(A) @ 1m +/- 3dB - Tone 2 [103dB(A) @ 10ft/3m]
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Adjustable -12dB(A) [Tone 2]
Effective range: 125m/410ft @ 1KHz
Stage switching: DC units - Positive or Negative line.
AC units - common supply line
Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 500,000 cd - calculated from energy (J)
Effective Intensity cd: 250 cd - calculated from energy (J)
Peak Candela: 33,410 cd - measured ref. to I.E.S.
Effective Intensity: 94.78 cd - measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life: Emissions are reduced to 70% after 8 million flashes
General:
Voltages DC: 24V dc [20-28Vdc]; 48V dc [38-58Vdc]
Voltages AC: 115V ac 50/60Hz; 230V ac 50/60Hz
Ingress protection: EN60529: IP66
UL50E / NEMA250: 4 / 4X / 3R / 13
Housing material: Marine grade aluminium Al Si12 Cu
Colour: Red (RAL3000), grey (RAL7038)
Cable entries: 2 x M20 x 1.5mm threaded gland entries
Terminals: 0.5 - 2.5mm² (20-14 AWG)
Grounding stud: M5
Operating temp: -40 to +70°C [-40° to +158°F] - Class I Div 2
-40 to +50°C [-40° to +122°F] - All other approvals
Relative humidity: 95%
Weight: DC: 2.80kg/6.16Ibs AC:3.10kg/6.82Ibs

Part Codes

Version: Part code:
Product type: D2xC1X05 Haz Loc alarm horn sounder & Xenon strobe beacon
Voltage: DC024
DC048
AC115
AC230
24V dc - UL/cUL Fire Alarm
48V dc
115V ac
230V ac
Cable Entry Type:[e]






Note:
A
B
C
D
E
F
G
2 x M20x1.5mm
2 x 1/2" NPT - adaptors
2 x 3/4" NPT - adaptors
2 x M25x1.5mm - adaptors
1 x 1/2" NPT - adaptor
1 x 3/4" NPT - adaptor
1 x M25x1.5mm - adaptor
M20 stopping plugs supplied for unused entries
Adaptor/Stopping
plug material: [m]
B
N
S
Brass
Nickel Plated
Stainless Steel
Variable: [s] 1
2
A2 (304) Stainless Steel Lens Guard
A4 (316) Stainless Steel Lens Guard
Product version: [v] A1 UL, cUL, IECEx & ATEX
Enclosure colour: [x] R
G
Red RAL3000
Grey RAL7038
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow

Alarm sounder

Version: Voltage: Current:
24V dc 10-30V dc 313mA [at nominal voltage]
48V dc 38-58V dc 181mA [at nominal voltage]
115V ac 50/60Hz +/-10% 90mA
230V ac 50/60Hz +/-10% 52mA

Coding

  • NEC / CEC: Class I Div 2 ABCD T2B Ta -40°C to +70°C 
    Class I Div 2 ABCD T2C Ta -40°C to +55°C 
    Class I Div 2 ABCD T2D Ta -40°C to +40°C 
    Class II Div 2 FG T5 Ta -40°C to +50°C 
    Class III Div 1&2 Ta -40°C to +50°C 
  • NEC: Class I Zone 2 AEx nA IIC T2 Gc (Ta -40°C to +50°C) 
    Zone 22 AEx tc IIIC 120°C Dc (Ta -40°C to +50°C) 
  • CEC: Class I Zone 2 Ex nA IIC T2B Gc X (Ta -40°C to +50°C) 
    Class I Zone 2 Ex nA IIC T2C Gc X (Ta -40°C to +45°C) 
    Zone 22 Ex tc IIIC 120°C Dc (Ta -40°C to +50°C) 
    Class II Div 2 EFG T4A Ta -40°C to +50°C 
  • IECEx & ATEX: II 3G Ex nA IIC T2 Gc (Ta -40°C to +50°C) 
    II 3D Ex tc IIIC 90°C Dc (Ta -40°C to +50°C)

Combined

Version: Voltage: Current:
24V dc 20-28V dc 518mA [at nominal voltage]
48V dc 42-54V dc 294mA [at nominal voltage]
115V ac 50/60Hz +/-10% 147mA
230V ac 50/60Hz +/-10% 61mA
Voltage & current details for Xenon & Horn components when powered from common power source

Xenon beacon

Version: Voltage: Current:
24V dc 20-28V dc 250mA [at nominal voltage]
48V dc 42-54V dc 149mA [at nominal voltage]
115V ac 50/60Hz +/-10% 70mA